:WPARameter<x>:HISTogram:MEASure:PAR
ameter:<Parameter>:VALue?
Function Queries the measured value of a histogram
parameter for waveform parameter measurement.
Syntax
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:<Parameter>:VALue?
<x> = 1 to 2
<Parameter> =
{C1|C2|DC|MAXimum|MEAN|
MEDian|MINimum|PEAK|SD2integ|
SD3integ|SDEViation|SDINteg}
Example
Below are examples for the maximum
:WPARAMETER1:HISTOGRAM:MEASURE:PARAM
ETER:MAXIMUM:VALUE?
-> :WPARAMETER1:HISTOGRAM:MEASURE:PA
RAMETER:MAXIMUM:VALUE 1.000E+00
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:POSition<y>
Function Sets or queries the position of a histogram
parameter for waveform parameter measurement.
Syntax
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:POSition<y> {<NRf>}
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:POSition<y>?
<x> = 1 to 2
<y> = 1 to 2
<NRf> = −5 to 5 (div)
Example
:WPARAMETER1:HISTOGRAM:MEASURE:PARAM
ETER:POSITION 1
:WPARAMETER1:HISTOGRAM:MEASURE:PARAM
ETER:POSITION?
-> :WPARAMETER1:HISTOGRAM:MEASURE:PA
RAMETER:POSITION 1
:WPARameter<x>:ITEM
Function Sets or queries a waveform parameter for
waveform parameter measurement.
Syntax
:WPARameter<x>:ITEM {<NRf>|MATH<y>|
PODA<y>|PODB<y>|PODL<y>,<Parameter>
[,2]}
:WPARameter<x>:ITEM?
<x> = 1 to 2
<NRf> = 1 to 8
<y> of MATH<y> = 1 to 4
<y> of PODA<y>, PODB<y>, PODL<y> = 0 to 7
<Parameter> =
{AMPLitude|AVERage|
AVGFreq|AVGPeriod|BWIDth|DELay|DT|
DUTYcycle|ENUMber|FALL|FREQuency|
HIGH|LOW|MAXimum|MINimum|
NOVershoot|NWIDth|PERiod|PNUMber|
POVershoot|PTOPeak|PWIDth|RISE|RMS|
SDEViation|TY1Integ|TY2Integ|V1|V2}
Example
:WPARAMETER1:ITEM 1,AVERAGE
:WPARAMETER1:ITEM?
-> :WPARAMETER1:ITEM 1,AVERAGE
Description The values that you can specify for <Parameter>
when <NRf> or MATH<y> is specified are
{AMPLitude|AVERage|AVGFreq|
AVGPeriod|BWIDth|DELay|DT|DUTYcycle|
ENUMber|FALL|FREQuency|HIGH|LOW|
MAXimum|MINimum|NOVershoot|NWIDth|
PERiod|PNUMber|POVershoot|PTOPeak|
PWIDth|RISE|RMS|SDEViation|TY1Integ|
TY2Integ|V1|V2}
.
The <Parameter> that you can set for
PODA<y>, PODB<y>, and PODL<y> are
{AVGFreq|DELay|DUTYcycle|FREQuency|
PERiod|PNUMber}
.
:WPARameter<x>:MODE
Function Sets or queries the waveform parameter
measurement mode.
Syntax
:WPARameter<x>:MODE {HISTogram|
TRENd}
:WPARameter<x>:MODE?
<x> = 1 to 2
Example
:WPARAMETER1:MODE HISTOGRAM
:WPARAMETER1:MODE?
-> :WPARAMETER1:MODE HISTOGRAM
:WPARameter<x>:TRENd?
Function Queries all trend display settings for waveform
parameter measurement.
Syntax
:WPARameter<x>:TRENd?
<x> = 1 to 2
:WPARameter<x>:TRENd:ASCale
Function Executes auto scaling of the trend display for
waveform parameter measurement.
Syntax
:WPARameter<x>:TRENd:ASCale
<x> = 1 to 2
Example
:WPARAMETER1:TREND:ASCALE
5.36 WPARameter Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals