:XY<x>:MEASure:CURSor:X<y>:STATe
Function Sets or queries the on/off status of the voltage of
an XY display horizontal cursor.
Syntax
:XY<x>:MEASure:CURSor:X<y>:STA
Te {<Boolean>}
:XY<x>:MEASure:CURSor:X<y>:STATe?
<x> = 1 to 4
<y> = 1 to 2
Example
:XY1:MEASURE:CURSOR:X1:STATE ON
:XY1:MEASURE:CURSOR:X1:STATE?
-> :XY1:MEASURE:CURSOR:X1:STATE 1
:XY<x>:MEASure:CURSor:X<y>:VALue?
Function Queries the voltage of a horizontal cursor in the
XY display.
Syntax
:XY<x>:MEASure:CURSor:X<y>:VALue?
<x> = 1 to 4
<y> = 1 to 2
Example
:XY1:MEASURE:CURSOR:X1:VALUE?
-> :XY1:MEASURE:CURSOR:X1:VALUE 1.00
0E+00
:XY<x>:MEASure:CURSor:Y<y>?
Function Queries all vertical cursor settings for the XY
display.
Syntax
:XY<x>:MEASure:CURSor:Y<y>?
<x> = 1 to 4
<y> = 1 to 2
:XY<x>:MEASure:CURSor:Y<y>:POSition
Function Sets or queries a vertical cursor position in the
XY display.
Syntax
:XY<x>:MEASure:CURSor:Y<y>:POSiti
on {<NRf>}
:XY<x>:MEASure:CURSor:Y<y>:POSition?
<x> = 1 to 4
<y> = 1 to 2
<NRf> = −4 to 4 (div)
Example
:XY1:MEASURE:CURSOR:Y1:POSITION 1
:XY1:MEASURE:CURSOR:Y1:POSITION?
-> :XY1:MEASURE:CURSOR:Y1:POSITION 1
.000E+00
:XY<x>:MEASure:CURSor:Y<y>:STATe
Function Sets or queries the on/off status of the voltage of
an XY display vertical cursor.
Syntax
:XY<x>:MEASure:CURSor:Y<y>:STA
Te {<Boolean>}
:XY<x>:MEASure:CURSor:Y<y>:STATe?
<x> = 1 to 4
<y> = 1 to 2
Example
:XY1:MEASURE:CURSOR:Y1:STATE ON
:XY1:MEASURE:CURSOR:Y1:STATE?
-> :XY1:MEASURE:CURSOR:Y1:STATE 1
:XY<x>:MEASure:CURSor:Y<y>:VALue?
Function Queries the voltage of a vertical cursor in the XY
display.
Syntax
:XY<x>:MEASure:CURSor:Y<y>:VALue?
<x> = 1 to 4
<y> = 1 to 2
Example
:XY1:MEASURE:CURSOR:Y1:VALUE?
-> :XY1:MEASURE:CURSOR:Y1:VALUE 1.00
0E+00
:XY<x>:MEASure:INTeg?
Function Queries all integration settings for the XY display.
Syntax
:XY<x>:MEASure:INTeg?
<x> = 1 to 4
:XY<x>:MEASure:INTeg:LOOP
Function Sets or queries the integration method for the XY
display
Syntax
:XY<x>:MEASure:INTeg:LOOP {CLOSe|
OPEN}
:XY<x>:MEASure:INTeg:LOOP?
<x> = 1 to 4
Example
:XY1:MEASURE:INTEG:LOOP CLOSE
:XY1:MEASURE:INTEG:LOOP?
-> :XY1:MEASURE:INTEG:LOOP CLOSE
:XY<x>:MEASure:INTeg:POLarity
Function Sets or queries the integration polarity for the XY
display.
Syntax
:XY<x>:MEASure:INTeg:POLarity {CCW|
CW}
:XY<x>:MEASure:INTeg:POLarity?
<x> = 1 to 4
Example
:XY1:MEASURE:INTEG:POLARITY CCW
:XY1:MEASURE:INTEG:POLARITY?
-> :XY1:MEASURE:INTEG:POLARITY CCW
:XY<x>:MEASure:INTeg:VALue?
Function Queries the integrated value for the XY display.
Syntax
:XY<x>:MEASure:INTeg:VALue?
<x> = 1 to 4
Example
:XY1:MEASURE:INTEG:VALUE?
-> :XY1:MEASURE:INTEG:VALUE 1.000E+0
0
:XY<x>:MEASure:MODE
Function Sets or queries the automated measurement
mode for the XY display.
Syntax
:XY<x>:MEASure:MODE {CURSor|INTeg|
OFF}
:XY<x>:MEASure:MODE?
<x> = 1 to 4
Example
:XY1:MEASURE:MODE CURSOR
:XY1:MEASURE:MODE?
-> :XY1:MEASURE:MODE CURSOR
5.37 XY Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals