5-252
IM DLM4038-17EN
:TRIGger{[:ATRigger]|:BTRigger}:CAN[
:IDData]:MSIGnal:SIGNal:DECimal<x>
Function Sets a signal reference value, which is one of
the ID and data conditions, for CAN bus signal
triggering in decimal notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CAN
[:IDData]:MSIGnal:SIGNal:
DECimal<x> {<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:CAN
[:IDData]:MSIGnal:SIGNal:DECimal<x>?
<x> = 1 to 2
<NRf> = See the DLM4000 Feature Guide for this
information.
Example
:TRIGGER:ATRIGGER:CAN:IDDATA:
MSIGNAL:SIGNAL:DECIMAL1 1
:TRIGGER:ATRIGGER:CAN:IDDATA:
MSIGNAL:SIGNAL:DECIMAL1?
-> :TRIGGER:ATRIGGER:CAN:IDDATA:MSIG
NAL:SIGNAL:DECIMAL1 1.000E+00
:TRIGger{[:ATRigger]|:BTRigger}:CAN[
:IDData]:MSIGnal:SIGNal:ITEM
Function Sets the signal item, which is one of the ID and
data conditions, for CAN bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CAN
[:IDData]:MSIGnal:SIGNal:ITEM {<Stri
ng>,<String>}
<String> = Up to 32 characters
Example
:TRIGGER:ATRIGGER:CAN:IDDATA:
MSIGNAL:SIGNAL:ITEM "Sig_Test",
"Mess_Test"
Description Set the signal item first and then the message
item.
:TRIGger{[:ATRigger]|:BTRigger}:CAN[
:IDData]:RTR
Function Sets or queries the RTR value, which is one of
the ID and data conditions, for CAN bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CAN
[:IDData]:RTR {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:CAN
[:IDData]:RTR?
Example
:TRIGGER:ATRIGGER:CAN:IDDATA:RTR ON
:TRIGGER:ATRIGGER:CAN:IDDATA:RTR?
-> :TRIGGER:ATRIGGER:CAN:IDDATA:R
TR 1
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR?
Function Queries all ID OR condition settings for CAN bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR?
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:ACK?
Function Queries all ID OR condition ACK settings for CAN
bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:ACK?
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:ACK:MODE
Function Sets or queries the ACK mode, which is one
of the ID OR conditions, for CAN bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:ACK:MODE {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:ACK:MODE?
Example
:TRIGGER:ATRIGGER:CAN:IDOR:ACK:MO
DE ON
:TRIGGER:ATRIGGER:CAN:IDOR:ACK:MODE?
-> :TRIGGER:ATRIGGER:CAN:IDOR:ACK:MO
DE 1
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:ACK:TYPE
Function Sets or queries the ACK condition, which is one
of the ID OR conditions, for CAN bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:ACK:TYPE {ACK|ACKBoth|NONack}
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:ACK:TYPE?
Example
:TRIGGER:ATRIGGER:CAN:IDOR:ACK:TY
PE ACK
:TRIGGER:ATRIGGER:CAN:IDOR:ACK:TYPE?
-> :TRIGGER:ATRIGGER:CAN:IDOR:ACK:TY
PE ACK
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:DATA?
Function Queries all data settings for the ID OR condition
for CAN bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CAN:
IDOR:DATA?
5.34 TRIGger Group