EasyManuals Logo

Zebra CC6000 User Manual

Zebra CC6000
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
DataWedge
74
Decoder Params
Use Decode Params to configure individual decoder parameters.
NOTE: Not all parameter options are available with all scanners. See the DataWedge app on each device for the available
scanners and parameter options.
Codabar
CLSI Editing - Enable this parameter to strip the start and stop characters and insert a space after the first,
fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires
this data format (default - disabled).
Length1 - Use to set decode lengths (default - 6). See Decode Lengths on page 79 for more information.
Length2 - Use to set decode lengths (default - 55). See Decode Lengths on page 79 for more information.
NOTIS Editing - Enable this parameter to strip the start and stop characters from a decoded Codabar
symbol. Enable this feature if the host system requires this data format (default - disabled).
Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
Code 11
Length1 - Use to set decode lengths (default - 4). See Decode Lengths on page 79 for more information.
Length2 - Use to set decode lengths (default - 55). See Decode Lengths on page 79 for more information.
Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
Report Check Digit - Transmit Code 11 data with or without the check digit. A check in the checkbox
indicates to send Code 11 data with check digit (default - disabled).
Verify Check Digit - Check the integrity of all Code 11 symbols to verify that the data complies with the
specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 barcode.
No Check Digit - Do not verify check digit.
1 Check Digit - Barcode contains one check digit (default).
2 Check Digits - Barcode contains two check digits.
Code128
Code128 Reduced Quiet Zone - Enables decoding of margin-less Code 128 barcodes (default - disabled).
Ignore Code128 FCN4 - When enabled, and a Code 128 barcode has an embedded FNC4 character, it will
be removed from the data and the following characters will not be changed. When the feature is disabled,
the FNC4 character will not be transmitted but the following character will have 128 added to it (default -
disabled).
Check ISBT Table - The ISBT specification includes a table that lists several types of ISBT barcodes that
are commonly used in pairs. If ISBT128 Concat Mode is set, enable Check ISBT Table to concatenate only
those pairs found in this table. Other types of ISBT codes are not concatenated. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
Enable GS1-128 - Set the GS1 128 subtype. A check in the checkbox indicates that the option is enabled
(default - enabled).
Enable ISBT128 - Set the ISBT128 subtype. A check in the checkbox indicates that the option is enabled
(default - enabled).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra CC6000 and is the answer not in the manual?

Zebra CC6000 Specifications

General IconGeneral
Megapixel5 MP
Supported video modes1080p
Operating system version11
Operating system installedAndroid
Product colorBlack
Display diagonal10.1 \
Display resolution1280 x 800 pixels
Display aspect ratio16:10
Connectivity technologyWired & Wireless
Number of displays supported-
Wi-Fi standards802.11a, 802.11b, 802.11g, Wi-Fi 4 (802.11n), Wi-Fi 5 (802.11ac)
Networking standardsIEEE 802.3at
Ethernet interface typeGigabit Ethernet
Ethernet LAN (RJ-45) ports1
Speaker power2 W
Number of speakers2
Compatible memory cardsMicroSD (TransFlash)
AC adapter input voltage110/220 V
AC adapter output current3 A
AC adapter output voltage5.4 V
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code85176920
Weight and Dimensions IconWeight and Dimensions
Depth201 mm
Width278 mm
Height36 mm
Weight980 g

Related product manuals