170
MAINTENANCE INSTRUCTIONS
E730  E730a 
CLEANING OF HEATING SYSTEM 
FILTERS 
Carry out regeneration of filters, installed 
under covering grilles above front glass 
outside the cabin, as necessary accord-
ing to the degree of clogging: 
 by dusting, 
 by purging using compressed air. 
Carry out checks of clogging every day. 
Replace strongly clogged filters. 
The safety cabin of the tractor is 
not equipped with any special fil-
ters of air sucked into the cabin. 
The filters do not protect the 
driver against effects of aerosols 
and other harmful substances! 
 
 
*AIR FILTER WITH ACTIVE CARBON 
Filters with active carbon are installed instead of the standard dust filter and re-
placement is carried out in the same way as in the common filters. The filter should 
be located with the white surface on the grid.  
The filter is used only when spraying pesticides, after the work the paper filter should 
be reinstalled, because the carbon filter would be choked with dust after a short pe-
riod of time. Upon work the re-circulation controller should be in the position “air is 
drawn into from the outside”. 
The fan controller should be in the position “fan maximum work”. 
  WARNING: The filter does not provide full protection against toxic 
substances. 
  When handling the filter, wear protective gloves. 
  Don’t clean the filter; don’t flush it with compressed air. 
DANGER: The filter with active carbon should be replaced after every 200 
hours or 36 months (manufacture date is stated on the filter). If you can smell 
pesticides in the cabin, replace the filter immediately and check the cabin 
sealing. Used filters should be disposed in special disposal centres.