SWT
GIGABIT/FAST ETHERNET SWITCH TYPE SWT 44/137
USER GUIDE - M0SWTA1903Iv09 - V09 March 2019
The third parameter, Syslog Log, is a Checkbox control. By default, it is NOT selected,
which means that a remote server is configured and the traces are NOT stored in the local
Log. When the control is selected, the traces are sent to the remote server and are also
stored in the local Log with the corresponding severity level.
The last parameter, Syslog Server IP, establishes the IP address of the Remote Syslog
server to which the information is sent.
The system can order the selective activation/deactivation of log information associated
to some operating blocks (see command log).
Through CLI it is possible to consult the local log files other than the current one (see
command show).
5.2 ADMINISTRATION
The equipment has an integrated HTTP server for management purposes. The server
supports the HTTP and the HTTPS protocols, and users can selectively enable their use
and the respective port.
FIGURE 24 Administration menu configuration page
The procedure for the installation of the certificates is described in section B.4 of
Appendix B, Data structure in CLI.