5.4.4 "Cover" mode
If the pool is equipped with a compable electric shuer (contact closed = shuer closed), it can be connected to the
appliance in order to automacally reduce chlorinaon when closed. This is known as "Cover" mode. Chlorinaon will
resume at the level determined by the programmes on opening the compable electric shuer.
Producon in "Cover" mode can be congured in the sengs of the main menu from "Low/Cover" mode.
"Low/Cover" mode can be congured from 0% to 30% in intervals of 10%. The programmes remain acve when the
appliance is in "Low/Cover" mode.
Check that the shuer is compable and is connected to the appliance on the low-voltage circuit, see “2.5 I
Electrical connecons”.
"Cover" mode is automacally acvated when the shuer is closed. The message "Cover" mode and the producon rate
are displayed on the screen.
"Cover" mode will end as soon as the shuer is completely open.
If the appliance is equipped with a Dual Link module, we recommend not connecng "Cover" mode. More specically,
chlorinaon is managed by the Dual Link module. In cases where "Cover" mode is connected in the presence of a Dual
Link module, chlorinaon will be performed when the shuer is closed, even if the ORP measurement is greater than
the setpoint value.
5.4.5 "Cold water" safeguard
In addion to displaying the water temperature, the temperature sensor is used to protect the cell, which is sensive to
cold water (reduced conducvity between the plates and thus an increase in voltage).
The temperature displayed in the top le corner of the home screen starts to ash at 15°C.
When the water temperature is less than or equal to 15°C, chlorine producon automacally switches to the rate dened
in "Low"/"Cover" mode (between 0 and 30%).
When the water temperature is less than or equal to 10°C, chlorine producon stops. The absence of chlorinaon at this
temperature is not an issue since bacterial development is slowed in cold water.
In addion to the ashing temperature display, the message "LOW TEMPERATURE" is displayed intermiently.
When the temperature rises to above 10°C, the producon rate is set to "Low"/"Cover"
When the temperature rises to above 15°C, chlorinaon is resumed at the operang rate set via the programmes.
5.4.6 Locking the interface
The appliance can be locked, which deacvates the buons on the user interface panel. Press both buons and
simultaneously for 3 seconds. This funcon can be accessed from any screen/menu.
Locking the appliance automacally redirects the user to the home screen. Press both buons and simultaneously
for 3 seconds to unlock the appliance.