47
5.4.4 "Cover" mode
If the pool is equipped with a compable electric shuer (contact closed = shuer closed), it can be connected to the
appliance in order to automacally reduce chlorinaon when closed. This is known as "Cover" mode. Chlorinaon will
resume at the level determined by the programmes on opening the compable electric shuer.
Producon in "Cover" mode can be congured in the sengs of the main menu from "Low/Cover" mode.
"Low/Cover" mode can be congured from 0% to 30% in intervals of 10%. The programmes remain acve when the
appliance is in "Low/Cover" mode.
Check that the shuer is compable and is connected to the appliance on the low-voltage circuit, see “2.5 I
Electrical connecons”.
"Cover" mode is automacally acvated when the shuer is closed. The message "Cover" mode and the producon rate
are displayed on the screen.
"Cover" mode will end as soon as the shuer is completely open.
If the appliance is equipped with a Dual Link module, we recommend not connecng "Cover" mode. More specically,
chlorinaon is managed by the Dual Link module. In cases where "Cover" mode is connected in the presence of a Dual
Link module, chlorinaon will be performed when the shuer is closed, even if the ORP measurement is greater than
the setpoint value.
5.4.5 "Cold water" safeguard
In addion to displaying the water temperature, the temperature sensor is used to protect the cell, which is sensive to
cold water (reduced conducvity between the plates and thus an increase in voltage).
The temperature displayed in the top le corner of the home screen starts to ash at 15°C.
When the water temperature is less than or equal to 15°C, chlorine producon automacally switches to the rate dened
in "Low"/"Cover" mode (between 0 and 30%).
When the water temperature is less than or equal to 10°C, chlorine producon stops. The absence of chlorinaon at this
temperature is not an issue since bacterial development is slowed in cold water.
In addion to the ashing temperature display, the message "LOW TEMPERATURE" is displayed intermiently.
When the temperature rises to above 10°C, the producon rate is set to "Low"/"Cover"
When the temperature rises to above 15°C, chlorinaon is resumed at the operang rate set via the programmes.
5.4.6 Locking the interface
The appliance can be locked, which deacvates the buons on the user interface panel. Press both buons and
simultaneously for 3 seconds. This funcon can be accessed from any screen/menu.
Locking the appliance automacally redirects the user to the home screen. Press both buons and simultaneously
for 3 seconds to unlock the appliance.