EasyManua.ls Logo

Zodiac pH Link - I Technical Specifications

Zodiac pH Link
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
1.2 I Technical specicaons
1.2.1 Chlorinator
Hydroxinator®
iQ 10
Hydroxinator®
iQ 18
Hydroxinator®
iQ 22
Hydroxinator®
iQ 35
Nominal chlorine producon 10 g/h 18 g/h 22 g/h 35 g/h
Nominal output current 2.8 A 3.6 A 5 A 7.2 A
Recommended mineral level -
minimum mineral level
4 g/L - 3.3 g/L min.
Power supply voltage
110 - 240V
50-60 Hz
Electrical power 200 W maximum
Protecon rang IP43
Cell throughput (minimum/
maximum)
5m³/h < 18m³/h
Maximum allowable pressure in
the cell
2.75 bar
Operang water temperature 5°C < 40°C
Frequency bands
2.400 GHz - 2.497 GHz
Radio output power +19.5 dBm
1.2.2 Oponal pH Link or Dual Link module
pH Link Dual Link
Supply voltage
Extra-low voltage (connected to the control box)
Peristalc pump ow rate
1.2 L/h
Maximum back pressure (injecon)
1.5 bar
pH and ORP sensor type
Combined (pH=blue/ORP=yellow)
pH correcon
pH minus only (hydrochloric acid or sulphuric acid)
pH minus dispensing
Proporonal cyclic
pH sensor calibraon
1 point or 2 points (pH 4 and pH 7)
ORP sensor tolerances
/
10 ppm maximum
(shock chlorinaon)
ORP sensor calibraon
1 point (470 mV)
Sensor cable length
3 metres
EN

Related product manuals