Chapter 3 Management Cards
IES4005M User’s Guide
25
Figure 8 ALARM Connector PIN Layout
A closed circuit on the ALARM input pins indicates an alarm.
Short circuit: Alarm status is ON
Open circuit: Alarm status is OFF
Note: The alarm input is only for dry contact without any power.
The IES signals an alarm when it detects an alarm on the ALARM input pins, the IES4005M is
overheated, the voltage readings are outside the tolerance levels, a fan failed, or another alarm
occurs.
3.2.4 MSC1002G Specifications
Note: The following table lists the MSC1002G’s specifications.
3.2.5 Gigabit Ethernet SFP Transceiver Specifications
See Chapter 29 on page 221 for optical specifications of the supported optical transceivers.
Table 6 Alarm Connector PIN Layout
PIN NO. NAME
1 Alarm input 1, normal close
2 Alarm input 1, common (FG)
3 Alarm input 2, normal close
4 Alarm input 3, normal close
5 Alarm input 3, common (FG)
6 Alarm input 2, common (FG)
7 Alarm input 4, normal close
8 Alarm input 4, common (FG)
PIN1
PIN8
Table 7 MSC1002G Specifications
ITEM VALUE
Dimensions 130 mm (w) x 223 mm (D) x 42.4 mm (H)
Maximum Power
Consumption
37 Watts
Weight 516g

Table of Contents