EasyManua.ls Logo

ZyXEL Communications IES4005M - Local Management Cable

ZyXEL Communications IES4005M
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Cables
IES4005M User’s Guide
50
7.4 Local Management Cable
The local management cable is used for debugging or local maintenance.
7.4.1 Application
The connections are as follows:
• The mini RJ-11 connector connects to the MSC1002G’s CONSOLE1 port.
• The DB-9 socket connects to a computer.
7.4.2 Appearance
The following figure shows a local management cable.
Figure 25 Mini RJ-11 DB-9 Cable
7.4.3 Pin Assignments
The following diagram and chart show the pin assignments of the cable.
Connectors cable terminal, gauge 4~4.5 mm recommended
Wire gauge 18 AWG, go up 1 gauge for a distance of more than 10 feet
Cross-sectional area of the conductor 0.8231 mm2
Table 34 Frame Ground Cable Specifications (continued)
ITEM DESCRIPTION