IES4005M User’s Guide 67
CHAPTER 9
The CLI
This chapter introduces the command line interface (CLI).
9.1 Accessing the CLI
Use any of the following methods to access the CLI.
9.1.1 Console Port
1 Connect your computer to the console port on the IES using the appropriate cable.
2 Use terminal emulation software with the following settings:
3 Press [ENTER] to open the login screen.
9.1.2 Local Access by Telnet
Follow these steps to access the CLI from a computer connected to the MGMT port.
1 Connect your computer to the MGMT port.
2 Open a Telnet session to the IES’s IP address. If this is your first login, use the default values.
Make sure your computer IP address is in the same subnet, unless you are accessing the IES
through one or more routers.
Table 45 Default Settings for the Console Port
SETTING DEFAULT VALUE
Terminal Emulation VT100
Baud Rate 115200 bps
Parity None
Number of Data Bits 8
Number of Stop Bits 1
Flow Control None
Table 46 Default Out Of Band Management IP Address and Subnet Mask
SETTING DEFAULT VALUE
IP Address 192.168.0.1
Subnet Mask 255.255.255.0