EasyManua.ls Logo

ZyXEL Communications XMG1930-30 - Add;Edit Subnet Based VLAN

ZyXEL Communications XMG1930-30
679 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 56 VLAN
XMG1930 Series User’s Guide
392
56.8.1 Add/Edit Subnet Based VLAN
Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > VLAN > Subnet Based VLAN
Setup screen to display this screen.
Figure 276 SWITCHING > VLAN > Subnet Based VLAN Setup > Add/Edit
The following table describes the labels in this screen.
Name This field shows the name the subnet based VLAN.
IP This field shows the IP address of the subnet for this subnet based VLAN.
Mask-Bits This field shows the subnet mask in bit number format for this subnet based VLAN.
VID This field shows the VLAN ID of the frames which belong to this subnet based VLAN.
Priority This field shows the priority which is assigned to frames belonging to this subnet based VLAN.
Select an entry’s check box to select a specific entry. Otherwise, select the check box in the
table heading row to select all entries.
Add/Edit Click Add/Edit to add a new entry or edit a selected one.
Delete Click Delete to remove the selected entry.
Table 205 SWITCHING > VLAN > Subnet Based VLAN Setup (continued)
LABEL DESCRIPTION
Table 206 SWITCHING > VLAN > Subnet Based VLAN Setup > Add/Edit
LABEL DESCRIPTION
Active Enable the switch button to activate the IP subnet VLAN you are creating or editing.
Name Enter up to 32 alphanumeric characters to identify this subnet based VLAN. The string should
not contain [ ? ], [ | ], [ ' ], [ " ] or [ , ].
IP Enter the IP address of the subnet for which you want to configure this subnet based VLAN.
Mask-Bits Enter the bit number of the subnet mask. To find the bit number, convert the subnet mask to
binary format and add all the 1’s together. Take “255.255.255.0” for example. 255 converts to
eight 1s in binary. There are three 255s, so add three eights together and you get the bit
number (24).
VLAN Enter the ID of a VLAN with which the untagged frames from the IP subnet specified in this
subnet based VLAN are tagged. This must be an existing VLAN which you defined in the
SWITCHING > VLAN > VLAN Setup > Static VLAN screen.
Priority Select the priority level that the Switch assigns to frames belonging to this VLAN.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.

Table of Contents

Related product manuals