BFB-3000 Set Up and Operations Manual
Document No: D100253 22
The ‘Level Bed’ function moves the extruder carriage around the corners of the bed so the
operator can adjust the bed bolts to achieve a level bed.
Check the bed is fitted correctly (page 14).
On the control panel select ‘Settings’, ‘Level Bed’ function and press enter:
RUN FILE
EXTRUDER MAPPING
MANUAL MOVE
EXTRUDER CONTROL
HOME TOOL HEAD
>
SETTINGS
EXTRUDER OFFSETS
>
LEVEL BED
SET Z HEIGHT
SET BED TYPE
GENERAL SETTINGS
Press Z+/- to raise the bed to adjust the gap between the hot end and bed. Start with
approximately 10 mm distance between the nozzle and the bed. This will enable
rough levelling.