ACS 160 Users Manual 19
Q Type Series and Technical Data
* 180 % of nominal current I
2N
**150 % of nominal current I
2N
*** No overloadability! Derate to 90 % when using 8 kHz switching frequency. Rating is not valid if the ACS 160 is installed on top of
a non ABB motor.
**** Follow local rules for cable cross-sections. Shielded motor cable is recommended when mounting the ACS 160 on the wall.
***** Fuse type: UL class CC or T. For non-UL installations IEC269gG.
ACS 160 is suitable for use in a circuit capable of delivering not more than 65 kA rms symmetrical amperes, 500 V.
Note! Use 75 °C (167 °F) rated power cable.
Motor Mounted Wall Mounted
Filterless
3~ Input U
1
380-500 V ±10 %
ACS 163-
1K1-
3-A/R
1K6-
3-A/R
2K1-
3-A/R
2K7-
3-A
4K1-
3-A/R
1K1-
3-D/U
1K6-
3-D/U
2K1-
3-D/U
2K7-
3-D
4K1-
3-D/U
Built-in filter
3~ Input U
1
380-480 V ±10 %
ACS 163- 1K1-
3-B/S
1K6-
3-B/S
2K1-
3-B/S
2K7-
3-B
4K1-
3-B/S
1K1-
3-E/V
1K6-
3-E/V
2K1-
3-E/V
2K7-
3-E
4K1-
3-E/V
Frame Size R1 R2 R1 R2
Nominal ratings
(See B)
Nominal motor P
N
kW /
Hp
0.55 /
0.74
0.75 /
1
1.1 /
1.5
1.5 2.2 /
3
0.55 /
0.74
0.75 /
1
1.1 /
1.5
1.5 2.2 /
3
Input current I
1N
A 1.6 2.2 3.2 4.1 6.0 1.6 2.2 3.2 4.1 6.0
Continuous output
current I
2N
A 1.8 2.4 3.4 4.1 5.4 1.8 2.4 3.4 4.1 5.4
Max. current I
max
*A 2.73.65.16.28.12.73.65.16.28.1
Max. starting
current **
A 3.2 4.3 6.1 7.4 9.7 3.2 4.3 6.1 7.4 9.7
Continuous output
current squared
torque I
2NSQ
***
A 2.2 2.8 3.8 5.0 6.6 2.2 2.8 3.8 5.0 6.6
Output voltage U
2
V0 - U
1
Switching
frequency f
SW
kHz 4 (Standard)
8 (Low noise)
Protection limits (See O)
Overcurrent (peak)A 7.19.51316217.19.5131621
Overvoltage:
Trip limit V DC 875
Undervoltage:
Trip limit V DC 333
Overtemperature
°C / (°F) 105 (221) (inside power module)
Max. wire sizes and screw torque of connectors
Power terminals
****
mm
2
single core: 4 (AWG 12), stranded: 2.5 (AWG 14) / torque 0.8 Nm
Control terminals mm
2
0.5 - 1.5 (AWG22...AWG16) / torque 0.4 Nm
Line fuse 3~ *****
ACS163-
A 4 4 6 10104 4 6 1010
Power losses (at nominal point)
Power circuit W 17 23 33 45 66 17 23 33 45 66
Control circuit W 16 17 18 19 20 18 19 20 21 22
Maximum cable lengths can be found in section EMC Instructions and Maximum Cable Lengths