3BHS799208 E01 REV E ACS5000 WATER-COOLED USER MANUAL 129/186
08 OPERATION
8.6.3 Emergency-off sequence
8.7 Starting the drive
1) Operation
2) ReadyRef
3) Emergency-off command
MCB opens
Inverter stop modulating
Speed coasts down
4) NotReadyOn
DANGER
Hazardous voltages!
To prevent unintentional contact with energized components, all
covers must be screwed in place.
The release dial of the door safety switches must be in the locked
position to prevent the doors of the medium voltage compartments
from being opened unintentionally during operation.
CAUTION
Cooling system starts automatically!
The cooling system can start automatically as soon as the auxiliary
voltage has been switched on.
NOTICE
When you start the drive system locally for the first time after
commissioning, have the following documents at hand:
“Appendix D Wiring diagrams to identify the circuit breakers to
be switched on
“Appendix A Additional manuals, manual of the water cooling unit
to check that the water cooling unit is ready for operation
“9 CDP control panel on page 139 for information on functions
and features of the CDP control panel