EasyManua.ls Logo

ABB ACS5000 - Page 38

ABB ACS5000
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
03 POWER ELECTRONICS AND CABINET FEATURES
3BHS799208 E01 REV E ACS5000 WATER-COOLED USER MANUAL 38/186
VSI-MF
The VSI design employs DC-link capacitors and provides a switched
voltage waveform. As a result of the multilevel topology, the drive
produces an optimum number of switching levels - 9 levels, phase to
phase. The resulting output waveform permits the application of standard
motors without decreasing the reliability and efficiency of the motor.
Figure 3-2 Switching levels
Figure 3-3 Principle of 9-level topology
(1) Volts
(2) Amps
(3) 50 Hz operation point
(4) Voltage
(5) Current
1
2
3
4
5
6
7
8
9
10000 V
5000 V
- 5000 V
- 10000 V
1
2
3
4 5
15000
10000
5000
0
-5000
-10000
-15000
2000
1500
1000
500
0
-500
-1000
-1500
-2000

Table of Contents

Related product manuals