II K 6-8
Operating Instructions
Parameter entries
The entries required during the guided commission-
ing procedure are divided into selection parameters
and value parameters.
Selection parameters are selected from a prede-
fined text list and confirmed.
The control panel display only shows one line of this
text list at a time. Therefore, the list must be scrolled
line by line, using the
keys. To confirm a
selection, press
(17(5
.
Line 1: Parameter number and parameter name.
Line 2: Line currently selected in the text list.
In the commissioning instructions, alternative lines of
a text list are displayed against a grey-shaded back-
ground.
Select the desired line using the
keys.
Confirm your selection by pressing
(17(5
.
Yes/No decisions are treated in the same manner as
selection parameters.
Value parameters are parameters with numerical
contents, whose values can be incremented or decre-
mented by pressing the
keys. Each key stroke
will increment or decrement the selected parameter
by 1.
Holding down one of these keys will cause the param-
eter value concerned to be increased or decreased
rapidly.
Confirm the desired values by pressing
(17(5
.
Line 1: Parameter number and parameter name.
Line 2: Parameter value.
During the guided commissioning procedure, all val-
ues which can be changed are displayed with an
underline. Use the
keys to change the values
and confirm the entry by pressing
(17(5
. This will take
you to the next step of the commissioning procedure.
Interrupting the guided commissioning procedure
The guided commissioning procedure can be inter-
rupted by pressing
0(18
. There are three posibilities for
selection for going on the process.
ðBack to the previous commissioning step.
ðContinue with the same step.
ðExit guided commission procedure.
Confirm your selection by pressing
(17(5
.
2.01 Macro Select
Standard
Man/Const Sp
Hand/Auto
Hand/MotPot
Jogging
Motor Pot
ext Field Rev
Torque Ctrl
OUTPUT MENU AUT O OF F HAND REM
LOC <RUN>
Armature Autotuning?
No
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
Yes
1.02 Arm Volt Nom
400V
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
Panel display
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
Exit Wizard
Previous
Continue
Exit