Appendix D - Examples for basic parameter programming
II K D-1
The experience has shown that certain parameters must be adapted in most applications.
These parameters show the following tables.
Table 1: Operation for armature control mode
Table 2: Operation for field control mode
Table 3: Operation for field control mode with speed-dependent current limitation
Table 4: Common parameters for the three operating modes
Operation for armature control mode
P
n
Base Speed
Pnorm
Armature control range
105
Table 1
Parameter
number
Parameter
name
Significance Contents Entry
101 Arm Cur Nom Nominal armature current Ia
nom
102 Arm Volt Nom Nominal armature voltage Ua
nom
103 Field Cur Nom Nominal field current Ie
nom
104 Field Volt Nom Nominal field voltage Ue
nom
105 Base Speed Nominal speed n
nom
106 Max Speed Nominal speed = (1.05) n
nom
201 Macro Select Application macro selection Selection
203 Stop Mode Stop mode selection Selection
204 Eme Stop Mode Emergency stop mode selection Selection
502 Speed Meas Mode EMF or tacho or encoder
(Initial start-up = EMF)
Selection
503 Encoder Inc Number of increments per rev.
(if parameter 502 = Encoder)
Number of
pulses
509 Accel Ramp Acceleration ramp sec
510 Decel Ramp Deceleration ramp sec
511 Eme Stop Ramp Emergency stop ramp
(if parameter 204 = Ramp)
sec
601 AI1 Scale 100%
Reference signal voltage at 100%
speed
10 V
602 AI1 Scale 0%
Reference signal voltage at 0% speed
0 V
701 Language Panel language selection Selection