II K 6-3
Operating Instructions
Panel mode: Parameter programming
The first nine menu items or parameter groups are
used for setting the drive parameters.
To access the desired parameter group, select the
group concerned using the scrolling functions and
confirm by pressing
(17(5
. The display now switches
to the parameter selection level. To access a param-
eter from this group, select and confirm the parameter
concerned as described above for the parameter
group. The number, name and underlined value of the
parameter selected is now displayed.
1 Motor Settings
2 Operation Mode
3 Armature
4 Field
5 Speed Controller
6 Input / Output
7 Maintenance
8 Fieldbus
9 MacroAdaptation
OUTP UT ME NU AUTO O FF HAND REM LOC <R UN>
1500rpm
440V 368A 1500rpm
OUTPUT MEN U AUTO OFF HAND REM
LOC <RUN>
0(18
0(18
1.01 Arm Cur Nom
200A
1.01 Arm Cur Nom
200 A
1.02 Arm Volt Nom
420 V
1.03 Field Volt Nom
3.8 A
......
......
......
1.12 Cur Lim Speed
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
0(18
(17(5
1.01 Arm Cur Nom
200A
OUTPUT MENU A UT O OFF HAND REM
LOC <RUN>
0(18
(17(5
0(18
(17(5
confirm value
cancel
2XWSXW GLVSOD\ 0 HQXVHOHFWLRQ 3DUDPHWHUVHOHFWLRQ 3DUDPHWHUFKDQJLQJ
Panel mode: Function selection
Set Typecode
Read Faultlogger
Factory Settings
Copy to Panel
Copy to Drive
Long/Short Par List
Panel Lock
LCD Contrast
Commissioning
OUTP UT ME NU AUTO O FF HAND RE M LO C <RUN>
1500rpm
440V 368A 1500rpm
OUTPUT MEN U AUTO OFF HAND REM
LOC <RUN>
0(18
0(18
2XWSXWGLVSOD\ 0HQXVHOHFWLRQ
Functions are selected in the menu selec-
tion mode and confirmed with
(17(5
.
The function concerned will be executed
immediately:
Only the underlined values can be changed with the
keys. To confirm a changed value, press
(17(5
. If you
want to preserve the original value, confirm this by
pressing the
0(18
key. Pressing
0(18
key will return you
to the parameter selection level.
Further parameters within the same group can be
selected directly. To switch to a different parameter
group, first press the
0(18
key to return to the menu
selection level, then select the next group using the
keys, etc.
Don't forget to upload parameters into the panel.