II K 4-40
Overview of Software
4.5.11 Signal definitions
Signal "At Set Point"
Speed reference reached.
Speed actual value Speed Act (5.05) correspondes
to speed reference value before ramp generator
Ramp In Act (5.33). The deviation between both is
less than ±1,56% (1/64) of parameter maximum speed
Max Speed (1.06). Signal At Set Point is independent
on ON and RUN command.
Signals "Speed > Lev1 / Speed > Lev2
Speed Level reached. Speed actual value Speed Act
(5.05) is equal or greater than value of parameter
Speed Level 1 / 2 (5.16 / 5.17). The permitted
hysteresis is -0,78% (1/128) of parameter Max Speed
(1.06). That means during rising speed the threshold
is exactly the value of Speed Level 1 / 2 (5.16 / 5.17),
during falling speed the threshold is Speed Level 1 /
2 (5.16 / 5.17) 0,78%. Signals Speed > Lev1 /
Speed > Lev2 are independent on ON and RUN
command.
n
t
5DPS,Q$FW
6SHHG$FW
Ramp In Act +1,56% of
Max Speed (1.06)
speed ref
$W6H W3RLQW 
At Set Point = 0
At Set Point = 0
Ramp In Act -1,56% of
Max Speed (1.06)
At Set Point
Speed Act (5.05)
Ramp In Act (5.33)
Comp
I1
I2
I1=I2
Signal "Overtemp Mot" / "Overtemp DCS"
in case of Alarm
Signal "Comm Fault"
If Cmd Location (2.02) = Bus the drive will trip in case
of fault F20- Communication Fault and will stop in
accordance to Comm Fault Mode (2.07). If Cmd
Location (2.02) = Makro depend or Terminals or
Key only an alarm A11-Comm Interrupt will be
shown and the drive will not trip.
n
t
Comp
I1
I2
I1=I2
6SHHG$FW
Speed > Lev 1/2
Speed Act (5.05)
Speed Level 1/2
(5.16/5.17)
Speed
Level 1
(5.16)
Speed
Level 2
(5.17)
Hysteresis = 0,78%
= Max Speed
(1.06) / 128
Hysteresis = 0,78%
= Max Speed
(1.06) / 128
6SHHG!/HY 
6SHHG!/HY 
6SHHG!/HY
6SHHG!/HY 
PTC (DCS / Motor-AI2)
Digital Output DOx
Overtemp Mot/Overtemp DCS
$ODUP$RU$
A4-Converter Temp:high
A5-Motor Temp high
Fan On
PTC (DCS / Motor-AI2)
)DXOW )RU)
F7-Converter Overtemp
F8-Motor Overtemp
Reset
Fan On
Drive trips
Digital Output DOx
Overtemp Mot/Overtemp DCS
okok
Fault
F20-Communication
Reset
Communication
faulty
Digital Output DOx
Comm Fault
Signal "Overtemp Mot" / "Overtemp DCS"