II K 6-9
Operating Instructions
Commissioning step Comments
Language
Select and confirm.
Macro
Select and confirm.
Detailed information abaut mac-
ros see ch. 4.2
Application Mac-
ros
Nominal armature voltage
see motor name plate
Nominal armature current
see motor name plate
Nominal field voltage
see motor name plate
Nominal field current
see motor name plate
Nominal speed
see motor name plate
7.01 Language
English
Deutsch
Francais
Italiano
Espanol
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
2.01 Macro Select
Standard
Man/Const Sp
Hand/Auto
Hand/MotPot
Jogging
Motor Pot
ext Field Rev
Torque Ctrl
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
1.02 Arm Volt Nom
50V
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
1.01 Arm Cur Nom
4A
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
1.04 Field Volt Nom
310V
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
1.03 Field Cur Nom
0.40A
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
1.05 Base Speed
100rpm
OUTPUT MENU AUTO OFF HAND REM
LOC <RUN>
Start of guided commissioning
Unexpected trouble during guided commissioning can be eliminated easily. Find
in the following chapters the reason and carry out the measures described there.
For faults, alarms and diagnosis messages,
see chapter 6.4
Troubleshooting
.
For other reasons,
see chapter 6.3
Useful hints for commssioning
.