II K 6-17
Operating Instructions
Manually commissioning
Short description for manual commissioning a
DCS400 via control panel.
Follow this guide if panel commissioning wizard has
failed.
Valid for software version 108.0 and higher.
Set parameters
Arm Cur Nom (1.01): see motor name plate
Arm Volt Nom (1.02): see motor name plate
Field Cur Nom (1.03): see motor name plate
Field Volt Nom (1.04): see motor name plate
Base Speed (1.05): see motor name plate
with Analogue Tacho feedback
Switch the drive ON and increase speed reference
slowly up to the value of Base Speed (1.05) by using
a reference potentiometer or by using the DCS 400
operating panel in LOCal mode.
Read parameter
Speed Ref (5.04); same as Base Speed!
Tacho Speed Act (5.06); same as Base Speed?; if
not turn Pot R115 till value of (5.06) is equal to value
of (5.04)
Switch the drive Off
Set parameters
Max Speed (1.06): see motor name plate
Field Low Trip (4.06): min. field curr. at max. field
weakening point (see mo-
tor name plate) minus 10%.
Set parameters
Eme Stop Mode (2.04): Coast
Speed Meas Mode (5.02): EMF
Contr Service (7.02): Fld Autotun
Contr Service (7.02): Arm Autotun
Set parameter
Speed meas Mode (5.02): Analog Tacho
In the following charts the main structure of the
different commissioning steps refering to the speed
measurement are given. For the specific information
related to the parameters and panel handling see the
corresponding chapters.
Armature control range Field weakening range
Set parameter
Contr Service (7.02): Flux Adapt
Switch the drive ON and increase speed reference
slowly up to the value of Base Speed (1.05)
Switch the drive ON and increase speed reference
slowly up to the value of Max Speed (1.06)
Set parameter
Max Speed (1.06): same as Base Speed
To complete commissioning refer to appendix D -
Examples for basic parameter programming.
Armature control range Field weakening range
Armature control range /
Field weakening range ?
Armature control range /
Field weakening range ?
Measure tacho voltage by using a volt meter and turn
Pot R115 till tacho voltage corresponds to Max
Speed.
Measure tacho voltage by using a volt meter and turn
Pot R115 till tacho voltage corresponds to Base
Speed.