II K 3-6
Technical data
3.4 Power section cooling
Fan assignment for DCS 400
Fan data for DCS 400 (data per fan)
Fan connection for DCS 400
Configuration 3
Configuration 2
Configuration 1
Table 3.4/2: Fan data for DCS 400
Table 3.4/1: Fan assignment for DCS 400
Monitoring the DCS 400 power section
The power sections are monitored by an electrically
isolated PTC thermistor detector. First an alarm will
be outputted, and - if the temperature continues to
rise - an error message. This will switch off the unit
in a controlled manner.
12 3X99: 45
L
N
9DF
12 3X99: 45
L
N
9DF
M
~
12 3X99:
M
~
45
M55 M56
M
~
12 3X99:
M
~
45
M55 M56
M
~
M
~
M57 M58
12 3X99: 45
L
N
9DF
12 3X99: 45
L
N
9DF
M55
M
~
12 345X99:
LN
L
N
HLWKHU9DF
RU9DF
Converter type Size Fan type Configuration
DCS 40x.0020...DCS 40x.0025 A1 no Fan -
DCS 40x.0045...DCS 40x.0140 A1 2x CN2B2 1
DCS 40x.0180...DCS 40x.0260 A2 2x CN2B2 1
DCS 40x.0315...DCS 40x.0350 A3 2x CN2B2 1
DCS 40x.0405...DCS 40x.0550 A3 4x CN2B2 2
DCS 40x.0610...DCS 40x.0820 A4 1x W2E200 (230 V) 3
DCS 40x.0610. 2...DCS 40x.0820. 2 A4 1x W2E200 (115 V) 3
DCS 40x.0900...DCS 40x.1000 A4 1x W2E250 (230 V) 3
DCS 40x.0900. 2...DCS 40x.1000. 2 A4 1x W2E250 (115 V) 3
Fan type
CN2B2 W2E200 W2E200 W2E250 W2E250
Rated voltage [V] 115; 1~ 230; 1~ 115; 1~ 115; 1~ 230; 1~
Tolerance [%] ±10 +6/-10 +6/-10 ±10 +6/-10
Frequency [Hz] 50 60 50 60 50 60 50 60 50 60
Power consuption [W] 16 13 64 80 64 80 120 165 135 185
Current consumption [A] 0.2 0.17 0.29 0.35 0.6 0.7 1.06 1.44 0.59 0.82
Stall current [A] < 0.3 < 0.26 < 0.7 < 0.8 <1.5 <1.8 <1.8 <1.8 <0.9 <0.9
Air volume, freely blowing [m
3
/h] 156 180 925 1030 925 1030 1835 1940 1860 1975
Noise levelt [dBA] 44 48 59 61 59 61 66 67 68 70
Max. ambient temperature [° C] < 60 < 75 < 75 60 60
Useful lifetime of fan
appr. 40000
h/60°
appr. 45000
h/60°
appr. 45000
h/60°
appr. 40000 h appr. 40000 h
Protection Stall Overtemperature