EasyManua.ls Logo

ABB IRB 1300 - Page 167

ABB IRB 1300
770 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 145.
3
xx2000001503
Remove the SMB cover attachment screws and
carefully open the cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
CAUTION
There are cabling attached to the cover. The
cover cannot be removed completely until the
connectors are removed.
4
xx2000001504
Disconnect the connectors.
SMB.J1
SMB.J2
R2.SMB
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
5
Remove the SMB cover completely from the base.6
Disconnecting the axis-1 motor connectors
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 145.
2
Continues on next page
Product manual - IRB 1300 167
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued

Table of Contents

Related product manuals