NoteAction
DANGER
Make sure all safety requirements are met
when performing the first test run.
8
Jogging the robot to zero position
NoteAction
Turn on the electric power to the robot.1
If the robot is not connected to the controller,
power must be supplied to the connector R1.MP
according to Supplying power to connector R1.MP
on page 66.
xx2000001520
Jog all axes to zero position.2
DANGER
Turn off all:
• electric power supply
• hydraulic pressure supply
• air pressure supply
to the robot, before entering the safeguarded
space.
3
Concluding procedure
NoteAction
For robots with protection type Clean Room:1
Clean and paint the joints that have been opened.
See Cut the paint or surface on the robot before
replacing parts on page 145.
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Calibration is detailed in section
Calibration on page 713.
Recalibrate the robot.2
Continues on next page
Product manual - IRB 1300 357
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the lower arm
Continued