NoteAction
Tightening torque: 3 NmRemove the tool and refit the plug screw.7
For robots NOT with protection
type Clean Room
For robots with protection type Clean Room
(option 3351-4)
Plug screw: 3HAC078352-001
xx2000001609
Refit the plug screw with the rubber washer.
For robots with protection type
Clean Room (option 3351-4)
Plug screw, Clean Room:
3HAC078351-001
Rubber sealing washer:
3HAC075325-001
xx2000002496
Routing the cable package in the lower arm
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate to the cable package.2
Tightening torque: 2.6 Nm
xx2000001554
Continues on next page