NoteAction
xx2000001532
Disconnect the connectors.
MP6
FB6
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
3
xx2000001533
Snap loose and remove the male head of the
connectors from the connector plate.
4
Disconnecting the axis-5 motor connectors
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 145.
2
Continues on next page
Product manual - IRB 1300 551
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the axis-5 motor
Continued