Separating the cable package from the housing
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 145.
2
xx2000001546
Remove the axis-4 cable protector.3
Disconnecting the axis-2 and -3 motor connectors
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 145.
2
xx2000001548
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
3
Continues on next page
600 Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.7.2 Replacing the axis-2 gearbox
Continued