xx2000001556
Remove the axis-2 cable protector.3
xx2000001557
Remove the cable brackets from the swing first
and then from the cable package.
4
xx2100001466
Pulling out the cable package
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 145.
2
Wrap the connectors with the masking tape.3
Continues on next page