EasyManua.ls Logo

ABB MicroFlex e190 - Derating

ABB MicroFlex e190
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data 149
Derating
The continuous output currents stated above must be derated if any of the following
conditions apply. The final derating factor is a multiplication of all applicable derating
factors.
Ambient temperature de
rating: 1.6 A models
A temperature derating is require
d when operating the 1.6 A models in ambient
temperatures between 45 °C (+113 °F) and the maximum of 50 °C (122 °F):
Ambient temperature
1.00
0.80
+45 °C +50 °C
+113 °F +122 °F
Derating factor for 1.6 A models:
Ambient temperature derating: 3 A, 6 A & 9 A models
No temperature derating is required in ambient temperatures up to the maximum of
55 °C (131 °F).
Altitude derating
At altitudes from 1000 to 2000 m (3280 to 6560 ft) abo
ve sea level, the derating is 1%
for every 100 m (328 ft). For a more accurate derating
, use the DriveSize PC tool.

Table of Contents

Other manuals for ABB MicroFlex e190

Related product manuals