Note/IllustrationAction
xx2200001972
Push the buckle of the digital base
slightly and take out the digital base.
2
Refitting the safety digital base device
Refitting the safety digital base device
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
xx2300001842
Continues on next page
Product manual - OmniCore V400XT 229
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.2.7 Replacing the safety digital base device
Continued