NoteArticle numberEquipment
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC082020-008Circuit diagram - OmniCore
V400XT
Removing the cable grommet assembly
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Opening the door on page 182.Open the door.2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
3
xx2300001842
Removing the cable grommet assembly
Note/IllustrationAction
Remove the cables out from the clips in
the cabinet carefully.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
1
Continues on next page
302 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.4 Replacing the cable grommet assembly
Continued