Note/IllustrationAction
Push the Ethernet outlet connector with
cable into the cabinet.
5
Disconnect all connectors from the unit
to be replaced.
6
Remove the cables out from the clips in
the cabinet carefully.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
7
Take the Ethernet outlet connector with
cable out from the upper side.
8
Refitting the Ethernet outlet connector with cable
Refitting the Ethernet outlet connector with cable
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
Insert the Ethernet outlet connector with
cable into the cover from inner side of
the cabinet.
3
Continues on next page
314 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.5 Replacing the Ethernet outlet connector with cable
Continued