Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
3
xx2300001842
Removing the LED indicator
Note/IllustrationAction
xx1900001926
Loose the attachment screws locking the
cable.
1
Remove the terminals (X1&X2) of the
cable from the lamp.
2
Turn the MON_LAMP screw anti-clock-
wise to remove the screw.
3
Take the LED indicator out.4
Continues on next page
318 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.6 Replacing the LED indicator
Continued