EasyManua.ls Logo

ABB OmniCore V400XT - Page 332

ABB OmniCore V400XT
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note/IllustrationAction
Open the cover.
CAUTION
Clean cover from metal residues before
opening.
Metal residues can cause shortage on
the boards which can result in hazardous
failures.
5
Disconnect all connectors from the unit
to be replaced.
6
xx2300001705
Remove the screws at the front of the
box.
7
Push the measurement unit inwards and
lift out of the box.
8
xx2300001706
Remove the attachment screws from the
mounting plate.
9
Pull out the measurement unit.10
Continues on next page
332 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the measurement unit
Continued

Table of Contents