Transportation and storage conditions
ValueParameter
-40°C (-40°F)Minimum ambient temperature
+55°C (+131°F)Maximum ambient temperature
+70°C (+158°F)Maximum ambient temperature (less than 24
hrs)
In accordance with ETSI EN 300 019-2-2 /
Environmental class 2.3
Shock and Vibration
(No severity reduction for horizontal axes)
Max. 5 g = 50 m/s
2
(11 ms)
After storage, the operating conditions inside the controller must be met for at least
6 hours before switching on the controller (see Operating conditions on page 39).
The robot controller shall be stored according to its IP classification (IP54), that is,
indoors, in an environment that is dry and dust-free. In addition, wind, temperature
fluctuations, and condensation shall be avoided.
See also Product specification - OmniCore V line.
Operating conditions
The table shows the allowed operating conditions for the controller.
ValueParameter
+5°C (+41°F)Minimum ambient temperature
+45°C (+113°F)Maximum ambient temperature
2,000 mMaximum ambient altitude
In accordance with ETSI EN 300 019-2-3 /
Environmental class 3.5 (3M5)
Shock and Vibration
(Random vibration)
Note
The humidity conditions shall apply with the environmental conditions EN
60721-3-3, climatic class 3K3. For temperatures 0-30°C, the relative humidity
must not exceed 85%. For temperatures exceeding 30°C, the absolute humidity
must not exceed 25g/m
3
.
If the environmental conditions in EN 60721-3-3, climatic class 3K3, are not
possible to meet at the installation site, desiccant bags can be placed inside the
controller to achieve corresponding conditions. The desiccant bags must be
replaced regularly to maintain approved operating conditions.
Protection classes
Protection class
(IEC 60529)
IP54Controller cabinet, inner compartment for
electronics