Operation Manual / Power2 850-M / 4.1 Low-pressure stage
4
Disassembly and assembly
Page 14 /
49
© Copyright 2015 ABB. All rights reserved.
HZTL4062_EN
Revision -
December 2015
4.3 Removing the air suction branch
Disconnect air line according to the instructions of the enginebuilder.
Dismantle insulation as far as necessary.
If present: Disconnect supply line for compressor cleaning from air suction branch.
Figure 4: Removing the air suction branch
1. Loop around air suction branch (82000) with lifting gear.
2. Loosen and remove nuts (72004). Remove washers (72003).
3. Remove and put down the air suction branch.

Table of Contents