Operation Manual / Power2 850-M / 4.1 Low-pressure stage
Page 16 /
© Copyright 2015 ABB. All rights reserved.
4.5 Axial clearance A prior to disassembly
Clearances outside the tolerance
Serious damage to engines or property can be caused by clearances
outside the tolerance and excessively worn parts.
Have the components assessed and, if necessary, replaced by an ABB
Turbocharging Service Station.
Figure 6: Measuring axial clearance A
The axial clearance (A) must be measured prior to removal and after installation of the
cartridge group.
Measure and note axial clearance (A).
0.32 ... 0.53
Table 6: Axial clearance A