Control dimension after installing cartridge group
Control dimension outside the tolerance value
If the control dimension is out of tolerance, the cartridge group has not been
correctly installed and can be the cause of serious damage to the machine
or property.
Remove and reinstall the cartridge group.
Always replace jammed gasket rings with new ones.
If the control dimension is still out of tolerance, contact an ABB
Turbocharging Service Station.
Figure 24: Measuring control dimension X
After installing the cartridge group, the control dimension (X) must be measured.
63.0 ±0.09
Table 10: Control dimension X