Operation Manual / Power2 850-M / 4.2 High-pressure stage
4 Disassembly and assembly / 4.6 Removing the cartridge group
© Copyright 2017 ABB. All rights reserved. HZTL4063_EN Revision A August 2017
CAUTION
Damage to cartridge group and toolbox cover
The turned-over toolbox cover may be only used for intermediate storage of
the cartridge group.
u The cover must be on a level surface.
u The cover may not be used to transport the cartridge group.
Fig.11: Moving out cartridge group 3
9. Put down the cartridge group in the holders of the turned-over toolbox cover (90010).
Pay attention to note concerning aligning the cover.
10. Remove plate(90032), screw(90656), nut(90415) and plates(90031).
11. Remove the lamellar rings (64001).
12. Remove O-rings(42017 / 42018).
Page 16 / 35