FEM630 | ELECTROMAGNETIC FLOWMETER | OI/FEM630-EN REV. A
Menu / parameter Description
Diagnostics / ...Diagnosis Values
All values in this menu are for informational and service purposes only.
Inhouse Temperature
Display of temperature value within the transmitter housing.Inhouse Temp MaxPeak
Inhouse Temp MinPeak
Driver Current Display of the drive current of the sensor coil.
Signal Region on ADC
Display of the measuring signal within the A / D converter input.

Coil DAC Preset Display of the D / A converter for coil drive.
DC Feedback DAC D / A converter feedback value.
ADC Errors A / D converter error
Device Restart Count Number of device restarts (boots).
Diagnostics / ......Simulation Mode
Simulation Switch
Manual simulation of measured values. After selecting the value to be simulated, a corresponding parameter is
displayed in the menu ‘Diagnostics / ......Simulation Mode’. The simulation value can be set here.
The output values correspond to the simulated flowrate entered.
The ‘Configuration’ information is displayed in the lower line of the display.
Only one measured value / output can be selected for simulation.
After power-up / restart of the device, the simulation is switched off.
Off
Qm Massflow [unit]

Qv Volumeflow [unit]














Hart Frequency