8 OI/FEP610/FEH610-EN Rev. B | ProcessMaster FEP610, HygienicMaster FEH610
2.1.3 Transmitter
Transmitter
Model FET612
Housing Integral mount design (see Fig. 2), remote mount design.
IP rating IP 65 / IP 67
Cable length Maximum 50 m (164 ft), remote mount design only
Power supply 100 ... 240 V AC (-15 / +10 %),
24 ... 48 V DC (-10% / +10 %)
Outputs Current output: 4 … 20 mA, active
Digital output 1: passive, configurable as pulse, frequency or switch output
Digital output 2: passive, configurable as pulse or switch output
Local display Configurable graphical display (option)
Approvals
— Further approvals At www.abb.com/flow or on request.