EasyManua.ls Logo

ADLINK Technology PCI-8102 - Continuous Motion; 8102_Dwell_Move; 8102_Set_Continuous_Move

ADLINK Technology PCI-8102
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Library 171
6.16 Continuous Motion
@ Name
_8102_set_continuous_move – toggle continuous
motion sequence flags
_8102_check_continuous_buffer – check if the
command register buffer is empty
_8102_dwell_move – Set a dwell move
@ Description
_8102_set_continuous_move():
This function is necessary before and after continuous motion
command sequences.
_8102_check_continuous_buffer():
This function is used to detect if the command pre-register is
empty or not. Once the command pre-register is empty, users may
write the next motion command into it. Otherwise, the new com-
mand will overwrite the previous command in the 2nd command
pre-register.
_8102_dwell_move:
This function is used to start a dwell move that means the move
does not cause real motion for a specific time.
Following example is shown how does the user
_8102_set_continuous_move( 2, 1 ); // start
continuous move
_8102_start_tr_move( 2, 20000.0, 10.0, 10000.0,
0.1, 0.1);
_8102_dwell_move( 2, 2000); //dwell move for 2
sec.
_8102_start_sr_move( 2, 20000.0, 10.0, 10000.0,
0.1, 0.1, 0, 0 );
_8102_set_continuous_move( 2, 0 ); //end
continuous move

Table of Contents