EasyManua.ls Logo

ADLINK Technology PCI-8102 - Origin Signal ORG

ADLINK Technology PCI-8102
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signal Connections 25
3.3 Origin Signal ORG
The origin signals (ORG0~ORG1) are used as input signals for the
origin of the mechanism. The following table lists signal names,
pin numbers, and axis numbers:
The input circuit of the ORG signals is shown below. Usually, a
limit switch is used to indicate the origin on one axis. The specifi-
cations of the limit switch should have contact capacity of +24V @
6mA minimum. An internal filter circuit is used to filter out any high
frequency spikes, which may cause errors in the operation.
When the motion controller is operated in the home return mode,
the ORG signal is used to inhibit the control output signals (OUT
and DIR). For detailed operations of the ORG signal, refer to sec-
tion 4.3.
P1 Pin No Signal Name Axis #
24 ORG0 1
58 ORG1 2
I_24V
1V max.
To motion IC
ORG
2.2K
EGND
Inside 81
P1
Å Switch
DGND
PS2805
VCC

Table of Contents