Function Library 127
6.4 Pulse Input/Output Configuration
@ Name
_8102_set_pls_iptmode – Set the configuration for
feedback pulse input.
_8102_set_pls_outmode – Set the configuration for
pulse command output.
_8102_set_feedback_src – Enable/Disable the
external feedback pulse input
@ Description
_8102_set_pls_iptmode:
Configure the input modes of external feedback pulses. There are
four types for feedback pulse input. Note that this function makes
sense only when the Src parameter in _8102_set_feedback_src()
function is enabled.
_8102_set_pls_outmode:
Configure the output modes of command pulses. There are 6
modes for command pulse output.
_8102_set_feedback_src:
If external encoder feedback is available in the system, set the Src
parameter in this function to an Enabled state. Then, the internal
28-bit up/down counter will count according to the configuration of
the _8102_set_pls_iptmode() function. Else, the counter will count
the command pulse output.
@ Syntax
C/C++ (DOS, Windows 95/NT)
I16 _8102_set_pls_iptmode(I16 AxisNo, I16
pls_iptmode, I16 pls_logic);
I16 _8102_set_pls_outmode(I16 AxisNo, I16
pls_outmode);
I16 _8102_set_feedback_src(I16 AxisNo, I16 Src);
Visual Basic (Windows 95/NT)
B_8102_set_pls_iptmode (ByVal AxisNo As Integer,
ByVal pls_iptmode As Integer, ByVal
pls_logic As Integer) As Integer

Table of Contents