3.6 Baler settings page
Fig. 13
(1) Target flake count
(2) Target bale length
(3) Knotter fan reverse interval
(4) Knotter lubrication interval
(5) Knotter lubrication duration
(6) Maintenance interval counter
(7) Maximum operating pressure
Icon Description
Target flake count
You must set the target for the flake count of a bale.
Target bale length
You must set the target bale length to the length of the bales that the baler
makes. This setting does not control the length of the bales. The knotter trip
arm controls the length of the bales mechanically.
Knotter fan reverse interval
You can set the period for the fan to operate before it operates in the reverse
direction for a short time.
Kotter lubrication interval
You can set how many bales the machine makes before the knotter lubrication
system operates.
Knotter lubrication duration
You can set the time that the knotter lubrication system operates for.