Step Diagnostic Result Action
4 Is the magnet tight on the
shaft?
Yes Go to step 5..
No Tighten the fasteners.
5 Is the magnet aligned
correctly with the sensor?
Yes Go to step 6.
No Adjust the magnet.
6 Is there unwanted
material in the space
between the sensor and
the magnet on the end of
the shaft?
Yes Clean the area between
the sensor and the
magnet on the end of the
shaft.
No Go to step 7.
7 Adjust the distance
between the sensor and
the magnet on the end of
the shaft to 1 mm (0 in) to
3 mm (0.1 in). Is the
problem corrected?
Yes Diagnostics complete.
No Refer to your approved
dealer.
5.3.2 PTO speed diagnostics
WARNING: The machine or parts can move without notification.
The parts that move can cause death or injury.
Before you do work on the machine:
If an implement is on the machine, lower the implement to the ground.
Stop the engine.
Remove the ignition key.
Disconnect the PTO shaft.
WARNING: Entanglement with the PTO shaft.
Risk of death or injury.
Make sure that the guards are in position and always operate correctly.
If a guard breaks or is missing, repair or replace it before you use the machine.
CAUTION: Personal Protective Equipment is mandatory.
This procedure can cause injury.
Put on Personal Protective Equipment when you do this procedure.
5 Troubleshooting
76
SimplEbale