Step Diagnostic Result Action
3 Does the Bale Count
operate correctly?
NOTE: The automatic
lubrication system
function is operated by the
Bale Count.
Yes Go to step 4.
No See Needle Carriage
Diagnostics.
4 Do a manual lubrication
cycle from the keypad.
Does the lubrication pump
operate for 15 seconds?
Yes Go to the Baler Settings
screen on the terminal
and change the
lubrication pump duration
and interval.
No Do a check of the
lubrication pump and
relay.
Do a check of the wiring to
the lubrication pump.
Do a check of the
lubrication pump. Use a
multimeter to see if there
is an internal short in the
lubrication pump motor.
5.3.8 Bale pressure system diagnostics
WARNING: The machine or parts can move without notification.
The machine and its parts are heavy and can cause death or injury.
Park the machine on a clean, hard and level area.
Set the parking brake to ON and install the wheel chocks.
If an implement is on the machine, lower the implement to the ground.
Stop the engine and remove the ignition key.
CAUTION: Personal Protective Equipment is mandatory.
This procedure can cause injury.
Put on Personal Protective Equipment when you do this procedure.
5 Troubleshooting
86
SimplEbale