Initializing and Provisioning
7705 SAR-A Chassis Installation Guide 113
Establishing Router Management Connections
There are three ways to access management of the 7705 SAR-A:
• console connection
• SSH connection
• Telnet connection
Console Connection
The Console port on the front of the 7705 SAR-A is a female RJ-45 connector (see
Figure 26). To establish a console connection, you need the following:
• an ASCII terminal or a PC running terminal emulation software set to the parameters
shown in Table 26
• a shielded RJ-45 CAT5e cable
Shielded cable must be used to maintain EMC compliance.
Figure 26: Console Port Connection
Table 26: Console Port Default Settings
Parameter Value
Gender DCE
Baud Rate 115 200
Data Bits 8
Parity None
Stop Bits 1
Flow Control None
7705 SAR-A
Mgmt
ToD Out
Lnk Act
Sync
In
+Batt A
-Batt A
+Batt B
-Batt B
Console
812111097654B3B2B1B1A
Status
2A 3A 4A
ActLnk ActLnk ActLnk ActLnk
Stat Stat Stat Stat
2468
1357
Lnk Act Lnk Act Lnk Act Lnk Act
Stat Stat Stat Stat
T1/E1Ethernet
-48 VDC
23319
Console port