Installing and Grounding the Chassis
7705 SAR-A Chassis Installation Guide 71
Before you begin, verify that:
• the equipment rack is securely installed, anchored, and grounded. Refer to the rack
manufacturer’s documentation for instructions.
• nearby equipment, including breaker panel bus bars and power connectors, is made
safe. Either shut off the power, if possible, or install safety guards or mats over
exposed power points and cables.
Required tools:
• a screwdriver appropriate for the rack-mount screws
To install the chassis in the rack:
Step 1. Lift the 7705 SAR-A and position it in the rack.
Step 2. Align the mounting holes on each bracket with the mounting holes on the rack
upright.
Insert a screw into each mounting hole and tighten each screw.
Step 3. Ground the chassis to the building ground. See Chassis Ground Wiring.
Table 14: Rack-Mounting Components
Key Description
1Equipment rack
2 Rack-mounting screws
3 7705 SAR-A chassis
4 Rack-mounting bracket